To correlate different CT system: MSCT (multislice com- puted tomography) with different acquisition parameters (100KV, 80KV), different reconstruction algorithm (ASIR) and CBCT (cone beam computed tomography) exami- nation in terms of absorbed X-ray dose and diagnostic ac- curacy. 80 KV protocols compared with 100 KV protocols result- ed in reduced total radiation dose without relevant loss of diagnostic image information and quality. CBCT protocols compared with 80 KV MSCT protocols resulted in reduced total radiation dose but loss of diagnostic image information and quality although no so relevant. In addition the new system applies to equipment ASIR ap- plicable on MSCT allows 50% of the dose without com- promising image quality.

L’obiettivo del presente lavoro è di correlare sistema TC differenti quali TC multistrato con differenti parametri di ac- quisizione (100KV, 80KV) e differenti algoritmi di ricostru- zione (ASIR) e CBCT (tomografia a fascio conico) in ter- mini di dose assorbita in raggi X e di accuratezza diagno- stica. Il protocollo con 80 KV rispetto a quello con 100 KV ha portato una riduzione di dose di radiazioni totale sen- za perdita rilevante di informazioni diagnostiche di quali- tà. Nella CBCT si ha una riduzione di dose di radiazione totale, con modesta perdita di informazioni e di qualità del- l’immagine. Il nuovo sistema di riduzione della dose ASIR applicabile alla TCMS consente di abbassare fino al 50% della dose di radiazioni senza compromettere assolutamente la qualità delle immagini.

Comparison of different dose reduction system in computed tomography for orthodontic applications

Lione, Roberta;
2011-01-01

Abstract

To correlate different CT system: MSCT (multislice com- puted tomography) with different acquisition parameters (100KV, 80KV), different reconstruction algorithm (ASIR) and CBCT (cone beam computed tomography) exami- nation in terms of absorbed X-ray dose and diagnostic ac- curacy. 80 KV protocols compared with 100 KV protocols result- ed in reduced total radiation dose without relevant loss of diagnostic image information and quality. CBCT protocols compared with 80 KV MSCT protocols resulted in reduced total radiation dose but loss of diagnostic image information and quality although no so relevant. In addition the new system applies to equipment ASIR ap- plicable on MSCT allows 50% of the dose without com- promising image quality.
2011
L’obiettivo del presente lavoro è di correlare sistema TC differenti quali TC multistrato con differenti parametri di ac- quisizione (100KV, 80KV) e differenti algoritmi di ricostru- zione (ASIR) e CBCT (tomografia a fascio conico) in ter- mini di dose assorbita in raggi X e di accuratezza diagno- stica. Il protocollo con 80 KV rispetto a quello con 100 KV ha portato una riduzione di dose di radiazioni totale sen- za perdita rilevante di informazioni diagnostiche di quali- tà. Nella CBCT si ha una riduzione di dose di radiazione totale, con modesta perdita di informazioni e di qualità del- l’immagine. Il nuovo sistema di riduzione della dose ASIR applicabile alla TCMS consente di abbassare fino al 50% della dose di radiazioni senza compromettere assolutamente la qualità delle immagini.
Multislice computed tomography
cone beam CT
radiation dose
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/161
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
social impact