To evaluate the soft tissue response to immediately placed implants using the platform switching concept.In 22 patients, 22 implants of 5.5 mm platform diameter were placed immediately into fresh extraction sockets in maxillae without compromised bone tissue. Eventual post-extraction bone defects were filled using bovine bone matrix mixed with collagen. Immediately after insertion, implants were randomly divided: 11 implants were connected with a 3.8 mm diameter abutment (test group) and 11 with a 5.5 mm diameter abutment (control group). A provisional crown was adapted and adjusted for non-functional immediate positioning. Two months later, definitive prosthetic rehabilitation was performed. Periodontal parameter, buccal peri-implant mucosal changes (REC), mesial and distal papilla height (PH) and vertical height of jumping distance (VHG) were measured at the time of implant placement, of definitive prosthesis insertion and every 6 months thereafter.The mean follow-up was 25 months. All implants were clinically osseointegrated.The test group showed a +0.18 mm REC gain. PH gain was +0.045 mm on average. The mean values were statistically significant (P <= 0.005) compared with the control group (PH=-0.88 mm; REC=-0.45 mm). No difference between the two groups in periodontal parameters was found. The mean value of bone filling was 7.51 mm in the test group (97.4% of VHG) and 8.57 mm in the control group (95.2% of VHG). No statistically significant difference was found between the two groups.This study suggests that, in a limited time period of 2 years, immediately placed implants with subsequent platform switching can provide peri-implant tissue stability.To cite this article:Canullo L, Iurlaro G, Iannello G. Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft tissue response. Preliminary report.Clin. Oral Impl. Res. 20, 2009; 414-420.doi: 10.1111/j.1600-0501.2008.01660.x.

Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft tissue response. Preliminary report

Canullo, Luigi;
2009-01-01

Abstract

To evaluate the soft tissue response to immediately placed implants using the platform switching concept.In 22 patients, 22 implants of 5.5 mm platform diameter were placed immediately into fresh extraction sockets in maxillae without compromised bone tissue. Eventual post-extraction bone defects were filled using bovine bone matrix mixed with collagen. Immediately after insertion, implants were randomly divided: 11 implants were connected with a 3.8 mm diameter abutment (test group) and 11 with a 5.5 mm diameter abutment (control group). A provisional crown was adapted and adjusted for non-functional immediate positioning. Two months later, definitive prosthetic rehabilitation was performed. Periodontal parameter, buccal peri-implant mucosal changes (REC), mesial and distal papilla height (PH) and vertical height of jumping distance (VHG) were measured at the time of implant placement, of definitive prosthesis insertion and every 6 months thereafter.The mean follow-up was 25 months. All implants were clinically osseointegrated.The test group showed a +0.18 mm REC gain. PH gain was +0.045 mm on average. The mean values were statistically significant (P <= 0.005) compared with the control group (PH=-0.88 mm; REC=-0.45 mm). No difference between the two groups in periodontal parameters was found. The mean value of bone filling was 7.51 mm in the test group (97.4% of VHG) and 8.57 mm in the control group (95.2% of VHG). No statistically significant difference was found between the two groups.This study suggests that, in a limited time period of 2 years, immediately placed implants with subsequent platform switching can provide peri-implant tissue stability.To cite this article:Canullo L, Iurlaro G, Iannello G. Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft tissue response. Preliminary report.Clin. Oral Impl. Res. 20, 2009; 414-420.doi: 10.1111/j.1600-0501.2008.01660.x.
2009
marginal tissue reaction
non-functional immediate loading
platform switching
post-extractive implant
File in questo prodotto:
File Dimensione Formato  
Canullo et al., 2009.pdf

non disponibili

Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 1.03 MB
Formato Adobe PDF
1.03 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/17016
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 110
social impact