Background: Poor anastomotic perfusion can cause anastomotic leaks (AL). Hyperspectral imaging (HSI), previously validated experimentally, provides accurate, real-time, contrast-free intestinal perfusion quantification. Clinical experience with HSI is limited. In this study, HSI was used to evaluate bowel perfusion intraoperatively. Methods: Fifty-two patients undergoing elective colorectal surgeries for neoplasia (n = 40) or diverticular disease (n = 12), were enrolled. Intestinal perfusion was assessed with HSI (TIVITA®, Diaspective Vision, Am Salzhaff, Germany). This device generates a perfusion heat map reflecting the tissue oxygen saturation (StO2) amount. Prior to anastomose creation, the clinical transection line (CTL) was highlighted on the proximal bowel and imaged with HSI. Upon StO2 heat map evaluation, the hyperspectral transection line (HTL) was identified. In case of CTL/HTL discrepancy > 5 mm, the bowel was always resected at the HTL. HSI outcomes were compared to the clinical ones. Results: AL occurred in one patient who underwent neoadjuvant radiochemotherapy and ultralow anterior resection for rectal cancer. HSI assessment was feasible in all patients, and StO2-values were significantly higher at proximal segments than distal ones. Twenty-six patients showed CTL/HTL discrepancy, and these patients had a lower mean StO2 (54.55 ± 21.30%) than patients without discrepancy (65.10 ± 21.30%, p = 0.000). Patients undergoing neoadjuvant radiochemotherapy showed a lower StO2 (51.41 ± 23.41%) than non-neoadjuvated patients (60.51 ± 24.98%, p = 0.010). Conclusion: HSI is useful in detecting intraoperatively marginally perfused segments, for which the clinical appreciation is unreliable. Intestinal vascular supply is lower in patients undergoing neoadjuvant radiochemotherapy, and this novel finding together with the clinical impact of HSI perfusion quantification deserves further investigation in larger trials.

Intraoperative bowel perfusion quantification with hyperspectral imaging: a guidance tool for precision colorectal surgery

Barberio, Manuel;
2022-01-01

Abstract

Background: Poor anastomotic perfusion can cause anastomotic leaks (AL). Hyperspectral imaging (HSI), previously validated experimentally, provides accurate, real-time, contrast-free intestinal perfusion quantification. Clinical experience with HSI is limited. In this study, HSI was used to evaluate bowel perfusion intraoperatively. Methods: Fifty-two patients undergoing elective colorectal surgeries for neoplasia (n = 40) or diverticular disease (n = 12), were enrolled. Intestinal perfusion was assessed with HSI (TIVITA®, Diaspective Vision, Am Salzhaff, Germany). This device generates a perfusion heat map reflecting the tissue oxygen saturation (StO2) amount. Prior to anastomose creation, the clinical transection line (CTL) was highlighted on the proximal bowel and imaged with HSI. Upon StO2 heat map evaluation, the hyperspectral transection line (HTL) was identified. In case of CTL/HTL discrepancy > 5 mm, the bowel was always resected at the HTL. HSI outcomes were compared to the clinical ones. Results: AL occurred in one patient who underwent neoadjuvant radiochemotherapy and ultralow anterior resection for rectal cancer. HSI assessment was feasible in all patients, and StO2-values were significantly higher at proximal segments than distal ones. Twenty-six patients showed CTL/HTL discrepancy, and these patients had a lower mean StO2 (54.55 ± 21.30%) than patients without discrepancy (65.10 ± 21.30%, p = 0.000). Patients undergoing neoadjuvant radiochemotherapy showed a lower StO2 (51.41 ± 23.41%) than non-neoadjuvated patients (60.51 ± 24.98%, p = 0.010). Conclusion: HSI is useful in detecting intraoperatively marginally perfused segments, for which the clinical appreciation is unreliable. Intestinal vascular supply is lower in patients undergoing neoadjuvant radiochemotherapy, and this novel finding together with the clinical impact of HSI perfusion quantification deserves further investigation in larger trials.
2022
Anastomotic leak
Bowel perfusion
Colorectal surgery
Hyperspectral imaging
Image-guided surgery
Optical imaging
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/19971
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
social impact