BACKGROUND/AIM: To compare patients affected by ankylosing spondylitis (AS) treated with anti-TNF-α for two years with controls in terms of Achilles tendon stiffness, ultrasound structure and thickness. PATIENTS AND METHODS: B-mode ultrasound evaluation and strain ultrasound elastography were performed in longitudinal and transverse planes on 22 Achilles tendons of 11 AS patients and 26 of 13 controls. RESULTS: There were no significant differences in thickness and stiffness of the Achilles tendon between AS patients and controls, except for an increased thickness in the middle third of the tendon in the AS patients (p=0.04). The Achilles tendon stiffness ratio of AS patients was 1.02±0.36 vs. 1.14±0.38 in the controls (p=0.2). CONCLUSION: AS patients had an Achilles tendon thickness greater than controls at the middle third, but no difference in the stiffness was found among them. Strain ultrasound elastography may be useful to exclude early changes in mechanical properties of tendons. KEYWORDS: Achilles tendon; ankylosing spondylitis; anti-TNF-α therapy; elastography; ultrasound

Strain Ultrasound Elastography in the Achilles Tendon of Ankylosing Spondylitis Patients Treated With Anti-TNF-α: A Preliminary Study.

Franceschi F
2019-01-01

Abstract

BACKGROUND/AIM: To compare patients affected by ankylosing spondylitis (AS) treated with anti-TNF-α for two years with controls in terms of Achilles tendon stiffness, ultrasound structure and thickness. PATIENTS AND METHODS: B-mode ultrasound evaluation and strain ultrasound elastography were performed in longitudinal and transverse planes on 22 Achilles tendons of 11 AS patients and 26 of 13 controls. RESULTS: There were no significant differences in thickness and stiffness of the Achilles tendon between AS patients and controls, except for an increased thickness in the middle third of the tendon in the AS patients (p=0.04). The Achilles tendon stiffness ratio of AS patients was 1.02±0.36 vs. 1.14±0.38 in the controls (p=0.2). CONCLUSION: AS patients had an Achilles tendon thickness greater than controls at the middle third, but no difference in the stiffness was found among them. Strain ultrasound elastography may be useful to exclude early changes in mechanical properties of tendons. KEYWORDS: Achilles tendon; ankylosing spondylitis; anti-TNF-α therapy; elastography; ultrasound
2019
Achilles tendon
ankylosing spondylitis
anti-TNF-α therapy
elastography
ultrasound
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/2254
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
social impact