We describe a case of a 63-years old woman affected by Hashimoto's thyroiditis and multinodular goiter. Her laboratory results showed elevated free triiodothyronine (FT3) concentrations (18.5 ng/L), with free thyroxine (FT4) and thyrotropin (TSH) within the physiologic range. On the basis of these results, she started methimazole therapy, with persistence of inappropriately elevated FT3 concentrations. The therapy was thus stopped and blood examination was repeated after one month in our laboratory: concentrations of thyroid tests were within the physiologic range, including FT3 (2.8 ng/L). The difference between this result and that previously obtained raised the suspicion of the presence of an interference in the first result. In fact, in our laboratory a competitive electrochemiluminescence immunoassay with labeled antibody is used, while the first laboratory employed a competitive chemiluminescence immunoassay with labeled analogue, which has a more important risk of interference. After treating sample by polyethylene glycol, FT3 resulted indeed normal also by the immunoassay used by the first laboratory.

Falsely increased free triiodothyronine values in a woman affected by thyroiditis and multinodular goiter

Paragliola R. M.;
2014-01-01

Abstract

We describe a case of a 63-years old woman affected by Hashimoto's thyroiditis and multinodular goiter. Her laboratory results showed elevated free triiodothyronine (FT3) concentrations (18.5 ng/L), with free thyroxine (FT4) and thyrotropin (TSH) within the physiologic range. On the basis of these results, she started methimazole therapy, with persistence of inappropriately elevated FT3 concentrations. The therapy was thus stopped and blood examination was repeated after one month in our laboratory: concentrations of thyroid tests were within the physiologic range, including FT3 (2.8 ng/L). The difference between this result and that previously obtained raised the suspicion of the presence of an interference in the first result. In fact, in our laboratory a competitive electrochemiluminescence immunoassay with labeled antibody is used, while the first laboratory employed a competitive chemiluminescence immunoassay with labeled analogue, which has a more important risk of interference. After treating sample by polyethylene glycol, FT3 resulted indeed normal also by the immunoassay used by the first laboratory.
2014
Valori falsamente aumentati di FT3
tiroidite
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/3951
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
social impact