Microplastics (MPs) have recently been acknowledged as a new major and ubiquitous environmental pollutant with still unclear, yet potentially high, risks for different ecosystems and human health. Nevertheless, quantitative identification protocols rely on long and subjective visual counting necessarily performed on microscopes by well-trained operators. In this study, an automatic, fast, portable, and inexpensive method for the quantitative detection of MPs in water is proposed. The system is based on the typical optical setup of a fluorescence confocal microscope specifically adapted to automatically count dye-stained MPs in flowing liquids using a low-power laser beam. The fluorescence pulses emitted by flowing MPs are revealed and processed by a specific software using a pattern recognition algorithm to discriminate and count real fluorescence pulses out of noise fluctuations. The system was calibrated with commercial orange fluorescent 10 µm and 1 µm polystyrene microspheres, and remarkable agreement with theoretical predictions was obtained regarding different parameters. Tests were also performed with laboratory-prepared MPs dispersed in different types of real water samples. In this case, the agreement with theory was slightly worse and differences found in the quantitative results require further investigation. However, the present study demonstrated the proof of concept of a method for quick automated MP counting in water.

Quantitative Detection of Microplastics in Water through Fluorescence Signal Analysis

Nicolai, Eleonora
2023-01-01

Abstract

Microplastics (MPs) have recently been acknowledged as a new major and ubiquitous environmental pollutant with still unclear, yet potentially high, risks for different ecosystems and human health. Nevertheless, quantitative identification protocols rely on long and subjective visual counting necessarily performed on microscopes by well-trained operators. In this study, an automatic, fast, portable, and inexpensive method for the quantitative detection of MPs in water is proposed. The system is based on the typical optical setup of a fluorescence confocal microscope specifically adapted to automatically count dye-stained MPs in flowing liquids using a low-power laser beam. The fluorescence pulses emitted by flowing MPs are revealed and processed by a specific software using a pattern recognition algorithm to discriminate and count real fluorescence pulses out of noise fluctuations. The system was calibrated with commercial orange fluorescent 10 µm and 1 µm polystyrene microspheres, and remarkable agreement with theoretical predictions was obtained regarding different parameters. Tests were also performed with laboratory-prepared MPs dispersed in different types of real water samples. In this case, the agreement with theory was slightly worse and differences found in the quantitative results require further investigation. However, the present study demonstrated the proof of concept of a method for quick automated MP counting in water.
2023
Drinking water
Fluorescence
Microplastics
MPs
Nile red
Quantitative detection
Water contaminants
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/6310
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
social impact