Poloxamer 338 (P338), a nonionic surfactant amphiphilic copolymer, is herein proposed as an anti-biofilm compound for the management of catheter-associated urinary tract infections (CAUTIs). P338’s ability to disrupt Escherichia coli biofilms on silicone urinary catheters and to serve as antibiotic enhancer was evaluated for biofilm-producing E. coli Ec5FSL and Ec9FSL clinical strains, isolated from urinary catheters. In static conditions, quantitative biofilm formation assay allowed us to determine the active P338 concentration. In dynamic conditions, the BioFlux system, combined with confocal laser scanning microscopy, allowed us to investigate the P338 solution’s ability to detach biofilm, alone or in combination with sub-MIC concentrations of cefoxitin (FOX). The 0.5% P338 solution was able to destroy the structure of E. coli biofilms, to reduce the volume and area fraction covered by adherent cells (41.42 ± 4.79% and 56.20 ± 9.22% reduction for the Ec5FSL and Ec9FSL biofilms, respectively), and to potentiate the activity of 1\2 MIC FOX in disaggregating biofilms (19.41 ± 7.41% and 34.66 ± 3.75% reduction in the area fraction covered by biofilm for Ec5FSL and Ec9FSL, respectively) and killing cells (36.85 ± 7.13% and 32.33 ± 4.65% increase in the biofilm area covered by dead Ec5FSL and Ec9FSL cells, respectively).

The Multifunctional Role of Poloxamer P338 as a Biofilm Disrupter and Antibiotic Enhancer: A Small Step forward against the Big Trouble of Catheter-Associated Escherichia coli Urinary Tract Infections

Vuotto C.
2022-01-01

Abstract

Poloxamer 338 (P338), a nonionic surfactant amphiphilic copolymer, is herein proposed as an anti-biofilm compound for the management of catheter-associated urinary tract infections (CAUTIs). P338’s ability to disrupt Escherichia coli biofilms on silicone urinary catheters and to serve as antibiotic enhancer was evaluated for biofilm-producing E. coli Ec5FSL and Ec9FSL clinical strains, isolated from urinary catheters. In static conditions, quantitative biofilm formation assay allowed us to determine the active P338 concentration. In dynamic conditions, the BioFlux system, combined with confocal laser scanning microscopy, allowed us to investigate the P338 solution’s ability to detach biofilm, alone or in combination with sub-MIC concentrations of cefoxitin (FOX). The 0.5% P338 solution was able to destroy the structure of E. coli biofilms, to reduce the volume and area fraction covered by adherent cells (41.42 ± 4.79% and 56.20 ± 9.22% reduction for the Ec5FSL and Ec9FSL biofilms, respectively), and to potentiate the activity of 1\2 MIC FOX in disaggregating biofilms (19.41 ± 7.41% and 34.66 ± 3.75% reduction in the area fraction covered by biofilm for Ec5FSL and Ec9FSL, respectively) and killing cells (36.85 ± 7.13% and 32.33 ± 4.65% increase in the biofilm area covered by dead Ec5FSL and Ec9FSL cells, respectively).
2022
antibiotic enhancer
biofilm disruption
catheter-associated urinary tract infections
E. coli
Poloxamer P338
File in questo prodotto:
File Dimensione Formato  
The Multifunctional Role of Poloxamer P338 as a Biofilm Disrupter and Antibiotic Enhancer A Small Step forward against the Big Trouble of Catheter-Associated Escherichia coli Urinary Tract Infections.pdf

accesso aperto

Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 7.46 MB
Formato Adobe PDF
7.46 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/7039
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
social impact