Introduction Research in the field of noninvasive ventilation (NIV) has contributed to the development of new NIV interfaces. However, interface tolerance plays a crucial role in determining the beneficial effects of NIV therapy. Areas covered This systematic review explores the most significant scientific research on NIV interfaces, with a focus on the potential impact that their design might have on treatment adherence and clinical outcomes. The rationale on the choice of the right interface among the wide variety of devices that are currently available is discussed here. Expert opinion The paradigm 'The right mask for the right patient' seems to be difficult to achieve in real life. Ranging from acute to chronic settings, the gold standard should include the tailoring of NIV interfaces to patients' needs and preferences. However, such customization may be hampered by issues of economic nature. High production costs and the increasing demand represent consistent burdens and have to be considered when dealing with patient-tailored NIV interfaces. New research focusing on developing advanced and tailored NIV masks should be prioritized; indeed, interfaces should be designed according to the specific patient and clinical setting where they need to be used.

The right interface for the right patient in noninvasive ventilation: a systematic review

Gregoretti, Cesare
2022-01-01

Abstract

Introduction Research in the field of noninvasive ventilation (NIV) has contributed to the development of new NIV interfaces. However, interface tolerance plays a crucial role in determining the beneficial effects of NIV therapy. Areas covered This systematic review explores the most significant scientific research on NIV interfaces, with a focus on the potential impact that their design might have on treatment adherence and clinical outcomes. The rationale on the choice of the right interface among the wide variety of devices that are currently available is discussed here. Expert opinion The paradigm 'The right mask for the right patient' seems to be difficult to achieve in real life. Ranging from acute to chronic settings, the gold standard should include the tailoring of NIV interfaces to patients' needs and preferences. However, such customization may be hampered by issues of economic nature. High production costs and the increasing demand represent consistent burdens and have to be considered when dealing with patient-tailored NIV interfaces. New research focusing on developing advanced and tailored NIV masks should be prioritized; indeed, interfaces should be designed according to the specific patient and clinical setting where they need to be used.
2022
CPAP
Interface
NIV
continuous positive pressure ventilation
custom mask
helmet
hybrid mask
mask
mouthpiece
nasal mask
nasal pillows
noninvasive ventilation
oral mask
oronasal mask
pressure support ventilation
total face mask
File in questo prodotto:
File Dimensione Formato  
The right interface for the right patient in noninvasive ventilation a systematic review_sep 22 (1).pdf

non disponibili

Licenza: Dominio pubblico
Dimensione 1.86 MB
Formato Adobe PDF
1.86 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/7623
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
social impact