Objective: Tubal patency in women with endometriosis has traditionally been evaluated by laparoscopy. The aim of this study was to investigate the accuracy of hysterosalpingo-contrast-sonography (HyCoSy) in the assessment of tubal patency in these women. Study design: A retrospective study was conducted at Physiopathology of Human Reproduction Unit. Infertile women who underwent HyCoSy and then a laparoscopy (dye test) within 6 months from the HyCoSy were included. Tubal patency was assessed by HyCoSy and the findings were compared with the results of laparoscopy, which was considered the gold standard for assessment of tubal patency. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) and positive and negative likelihood ratios (Lh+, Lh-) were calculated including the 95% confidence interval (CI). Results: A total of 1452 women underwent HyCoSy and 126 of them received a laparoscopy within 6 months from the HyCoSy. Of the 126 women, 42(33.3%) had a diagnosis of pelvic endometriosis and 84 (66.7%) had no endometriosis. In the endometriosis population, HyCoSy showed a sensitivity, specificity, PPV, NPV, Lh+ and Lh- of 85% (95% CI 62-96), 93% (95% CI 82-97), 81% (95% CI 58-94), 94% (95% CI 84-98), 12.6 (95% CI 4.8-33) and 0.15 (95% CI 0.05-0.4) respectively. In the non-endometriosis group, HyCoSy showed a sensitivity, specificity, PPV, NPV, LR+ and LR- of 85% (95% CI 65-95), 93% (95% CI 87-96), 71% (95% CI 53-85), 97% (95% CI 92-99), 13.2(95% CI 6.9-25) and 0.15(95% CI 0.06-0.3) respectively. The diagnostic accuracy of HyCoSy was 91% in the endometriosis group and 92% in the non-endometriosis patients. Conclusions: HyCoSy showed high accuracy in evaluating tubal patency in infertile non-endometriosis women and in those affected by endometriosis. (C) 2015 Elsevier Ireland Ltd. All rights reserved.

Hysterosalpingo-contrast-sonography (HyCoSy) in the assessment of tubal patency in endometriosis patients

Moro, Francesca;
2015-01-01

Abstract

Objective: Tubal patency in women with endometriosis has traditionally been evaluated by laparoscopy. The aim of this study was to investigate the accuracy of hysterosalpingo-contrast-sonography (HyCoSy) in the assessment of tubal patency in these women. Study design: A retrospective study was conducted at Physiopathology of Human Reproduction Unit. Infertile women who underwent HyCoSy and then a laparoscopy (dye test) within 6 months from the HyCoSy were included. Tubal patency was assessed by HyCoSy and the findings were compared with the results of laparoscopy, which was considered the gold standard for assessment of tubal patency. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) and positive and negative likelihood ratios (Lh+, Lh-) were calculated including the 95% confidence interval (CI). Results: A total of 1452 women underwent HyCoSy and 126 of them received a laparoscopy within 6 months from the HyCoSy. Of the 126 women, 42(33.3%) had a diagnosis of pelvic endometriosis and 84 (66.7%) had no endometriosis. In the endometriosis population, HyCoSy showed a sensitivity, specificity, PPV, NPV, Lh+ and Lh- of 85% (95% CI 62-96), 93% (95% CI 82-97), 81% (95% CI 58-94), 94% (95% CI 84-98), 12.6 (95% CI 4.8-33) and 0.15 (95% CI 0.05-0.4) respectively. In the non-endometriosis group, HyCoSy showed a sensitivity, specificity, PPV, NPV, LR+ and LR- of 85% (95% CI 65-95), 93% (95% CI 87-96), 71% (95% CI 53-85), 97% (95% CI 92-99), 13.2(95% CI 6.9-25) and 0.15(95% CI 0.06-0.3) respectively. The diagnostic accuracy of HyCoSy was 91% in the endometriosis group and 92% in the non-endometriosis patients. Conclusions: HyCoSy showed high accuracy in evaluating tubal patency in infertile non-endometriosis women and in those affected by endometriosis. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
2015
Endometriosis
Fallopian tube patency tests
HyCoSy
Infertility
Laparoscopy
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/7789
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
social impact