Metallosis represents a rare and severe complication of knee replacement surgery. It is caused by the infiltration and accumulation of metallic debris into the peri-prosthetic structures, deriving from friction between metallic prosthetic components. In knee arthroplasty, this event generally occurs as a result of polyethylene wear of the tibial or metal-back patellar component. The real incidence of metallosis is still unknown, although it seems to be more frequent in hip than in knee arthroplasty. The metallic debris induces a massive release of cytokines from inflammatory cells, making a revision necessary whenever osteolysis and loosening of the prosthesis occur. We report four patients who underwent revision of their knee arthroplasty because of severe metallosis. In one of these patients, polyethylene wear had determined friction between the metal-back patellar component and the anterior portion of the femoral component. In the remaining three cases, metallosis was caused by friction between the femoral and tibial prosthetic metal surfaces, resulting from full-thickness wear of the tibial polyethylene. T lymphocytes were activated by metal particles present in periprosthetic membranes. In all patients, one-stage revision was necessary, with rapid pain disappearance and a complete functional recovery of the knee joint. Copyright © by BIOLIFE, s.a.s

Metallosis following knee arthroplasty: an histological and immunohistochemical study

Cerciello, Simone;
2011-01-01

Abstract

Metallosis represents a rare and severe complication of knee replacement surgery. It is caused by the infiltration and accumulation of metallic debris into the peri-prosthetic structures, deriving from friction between metallic prosthetic components. In knee arthroplasty, this event generally occurs as a result of polyethylene wear of the tibial or metal-back patellar component. The real incidence of metallosis is still unknown, although it seems to be more frequent in hip than in knee arthroplasty. The metallic debris induces a massive release of cytokines from inflammatory cells, making a revision necessary whenever osteolysis and loosening of the prosthesis occur. We report four patients who underwent revision of their knee arthroplasty because of severe metallosis. In one of these patients, polyethylene wear had determined friction between the metal-back patellar component and the anterior portion of the femoral component. In the remaining three cases, metallosis was caused by friction between the femoral and tibial prosthetic metal surfaces, resulting from full-thickness wear of the tibial polyethylene. T lymphocytes were activated by metal particles present in periprosthetic membranes. In all patients, one-stage revision was necessary, with rapid pain disappearance and a complete functional recovery of the knee joint. Copyright © by BIOLIFE, s.a.s
2011
Cytokines
Knee arthroplasty
Metallic debris
Metallosis
Polyethylene wear
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.14245/9909
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 28
social impact